5 Parameter Patient Monitor 12.1" Supplied by Atico Medical \ Technical Specification:- Quality Standards and Classification CE, IS013485 SFDA: Class II b Anti-electroshock degree: Class I equipment (internal power supply) TEMP/SpO 2 /NIBP: BF ECG/Resp: CF \ Application Range Adult / Paediatric / Neonatal / Medicine / Surgery / Operating Room / lCU / CCU Display 12.1" real color TFT screen \ Environment Operating environment : Temperature: 0 ~40 C Humidity: 15%~80% Pressure: 86.0 kPa~106.0kPa Transport and Storage environment : Temperature: -20 ~55 C Humidity: 10%~90% Pressure: 86.0 kPa~106.0kPa \ Power Requirements AC: 100 - 240V, 50Hz/60Hz DC: Built-in rechargeable battery Battery: 11.1V 24wh Li-ion battery 2h operating after full charge 5min operating after low battery alarm \ Dimension and Weight Equipment: 340mm x 245mm x134 mm (about); 2.798kg (about) Package: 380mm x350 mm x 300mm; 4.598 kg (about) \ Date Storage Trend diagram/table: 7x24h N I BP review: 400 events Wave review: 100min Alarm review: 100 alarm events Support drug concentration titration analysis \ ECG 5 Leads: RA, LA, LL, RL, V Lead mode: I, II, III, AVR, AVL, AVF, V Gain: x 1.25mm/mV,2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV (error≥ 5%) Sweep speed: 6.25mm/s,12.5mm/s,25mm/s, 50mm/s (error ≥ ± 10%) Bandwidth: Surgery 1~25 Hz Monitor 0.5 ~40 Hz Diagnostic 0.05 ~130 Hz Sensitivity: >200 µ V P-P CMRR: ≥112dB Differential Input Impedance: >5M ohm Electrode Offset Potential: ±300mV Polarization Voltage: ≥ ± 500mV Input Impedance: ≥ 5 M Calibration Voltage: 1 mV ± 5% \ ST Segment ST Segment Range: -2.0mV ~ +2.0mV Accuracy: 0.02mV \ NIBP Method: Oscillometry Measure mode: Manual, Auto, STAT Measure interval in auto mode: 1~5/10/15/30/60/90/120/180/240/480min Measure period in STAT mode: 5min Pulse rate range: 40 ~240bpm Measure & alarm range: Adult SYS 40~280mmHg DIA 10~220mmHg MEAN 20~240mmHg Paediatric SYS 40~220mmHg DIA 10~160mmHg MEAN 20~170mmHg Neonatal SYS 40~135mmHg DIA 10~100mmHg MEAN 20~110mmHg Static pressure measurement Range: 0 ~ 300mmHg Accuracy: ± 3mmHg Resolution: 1 mmHg Accuracy: Max. Mean Error: ± 5mmHg Max. Standard Deviation: 8mmHg Overpressure protection: Adult 300mmHg Paediatric 240mmHg Neonatal 150mmHg Sp02 Measurement range: 0~100% Resolution: 1% Accuracy: 70%~100% ± 2% 40%~69% ± 3% \ Pulse Rate Measure/alarm range: 20 ~300bpm Resolution: 1 bpm Accuracy: ± 3bpm \ RESP Method: impedance between RA-LL Resp Impedance range: 0.3 - 3 ? Base Impedance range: 200 Q - 4000 ? Bandwidth: 0.3~2.5Hz Gain: x 0.25, x 0.5, x 1, x 2, x 4 Resp rate: Measurement Range Adult 0~120BrPM Neonatal/Paediatric 0~150BrPM Resolution: 1BrPM Accuracy: 7~150BrPM (± 2BrPM) 0 - 6BrPM (unspecified) Apnea Alarm: 10 ~40s \ TEMP Channel 2 Measure & alarm range: 0~50 °C Resolution: 0.1 °C Accuracy (no sensor): ±0.1 C (0~50 °C) \ Standard accessories • NIBP cuff & tube • ECG cable & electrodes • SpO2 sensor • TEMP probe • Lithium-ion battery • Power cable • Operators manual We are Exporters and Suppliers of 5 Parameter Patient Monitor 12.1" at wholesale competitive prices from India. \ Model No : IEPM 110 5 Parameter Patient Monitor 12.1"