Ventilator Vertical Diamond Supplied by Atico Medical \ Specification :- Ventilator Vertical Diamond is a multi-functional Ventilator adopting pneumatic, electronic control and microcomputer technology. Exported components are utilized to guarantee operational stability and reliability. With color screen (TEF) to display various measuring and configuration parameters, the device is very suitable for respiratory treatment, applicable for medical, surgical and gynecological departments, the department of pediatrics, first aid, and ICU departments of hospitals at different levels. Ventilator Display Mode : High-definition 10.4” TFT color LCD screen display Ventilation Mode : VCV,PCV,SIMV,PSV,PSV+SIMV,CPAP Ventilation Function : PEEP,SIGH, IRV, IP,Standby Ventilation Parameters : Tidal volume 20~1800 ml Rate 2~120bpm SIMV rate 2~120bpm I:E 4:1~1:8 Pressure trigger sensitivity -10~10 cmH2O Flow trigger sensitivity 1~20L/min PEEP 0~25 cm H2O Pressure Range 3~50 cm H2O Pressure limitation 5~60 cm H2O Pressure slope 1~10 gear Flow rate setting 1~10 gear Time control 1~10s SIGH 1.5 times the inspiratory time (60-120 adjustable) Inspiratory platform 0~50% Oxygen concentration 21%~99% Parameters for ventilation monitoring Expired tidal volume, Inhale tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous inspiratory rate, I/E, peak pressure of airway, average pressure, PEEP, inspiratory trigger pressure, Inspiratory platform, oxygen concentration, battery capacity, pressure - time waveform, flow rate - time waveform, flow-volume loop, pressure-volume loop Security Alarm System Oxygen Concentration alarm : Upper limit setting range 21%~99% Low limit setting range 18%~80% Airway pressure alarm : Upper limit setting range 5~60 cmH2O Low limit setting range 0~50 cmH2O Per-minute ventilation volume alarm : Upper limit setting range 1~20L/min Low limit setting range 0~19L/min Tidal volume : Upper limit setting range 10~1800ml Low limit setting range 0~1700ml Respiratory rate : Upper limit setting range 10~99bpm Low limit setting range 0~50bpm Sustained high-pressure alarm : It will give alarm when stress have consistentlybeen higher than 30 cm H2O Suffocation alarm : Power alarm Low pressure of oxygen alarm : Intubation off alarm Low pressure of Air alarm : Battery voltage alarm Power : AC 220V 50Hz (UPS, Storage battery) Mechanical Arms Air Compressor : With standby function We are Exporters and Suppliers of Ventilator Vertical Diamond at wholesale competitive prices from India. \ For More Information, visit us atwww.anesthesiaproductsindia.com \ Model No : APVE 141 Ventilator Vertical Diamond